2010 voltage reg
- vailvalley59
- 430 crawler
- Posts: 51
- Joined: Fri Apr 11, 2014 7:50 am
- Location: PA
2010 voltage reg
Would anyone know the NAPA part number for a voltage regulator for my 2010 diesel? (positive ground) I suspect that it is not working as it should--did test on generator and it seems to be OK. Thanks much
2010 diesel loader, IH 886, Cat 1947 D4 dozer, IH 966, Ford 7000, IH 2500, IH 706 and other toys
-
- MC crawler
- Posts: 4
- Joined: Wed Aug 20, 2014 8:25 am
ECH VR898 $102 ....MPE VR898SB $82 ....both Napa#s..... http://www.ebay.com/itm/Voltage-Regulat ... 30&vxp=mtr ...... $37 shipped .....
http://www.ebay.com/itm/8040-6173-New-R ... 4f&vxp=mtr ...... $63 plus $15 shipping
http://www.ebay.com/itm/8040-6173-New-R ... 4f&vxp=mtr ...... $63 plus $15 shipping
2010 with 622 dozer with mod. 35 ripper and a 2010 with 622 dozer bought in 1969 and a 2010 loader with drott and mod. 36 ripper
- vailvalley59
- 430 crawler
- Posts: 51
- Joined: Fri Apr 11, 2014 7:50 am
- Location: PA
2010 regulator
Thank you all--I am still testing to be sure the generator is putting out what it should--found NOS unit on e-bay also !! Everything was working fine two days ago.
2010 diesel loader, IH 886, Cat 1947 D4 dozer, IH 966, Ford 7000, IH 2500, IH 706 and other toys
if the Gen is bad put an alternator on it and get rid of the junk gen ..... here is one of my 2010s look at pic #2 how well a delco fits http://www.jdcrawlers.com/messageboard/ ... php?t=7806
2010 with 622 dozer with mod. 35 ripper and a 2010 with 622 dozer bought in 1969 and a 2010 loader with drott and mod. 36 ripper
- vailvalley59
- 430 crawler
- Posts: 51
- Joined: Fri Apr 11, 2014 7:50 am
- Location: PA
positive ground
Did you have to change the positive ground system to use Delco alternator?
I have several of them around but all came from negative ground systems. Thanks
I have several of them around but all came from negative ground systems. Thanks
2010 diesel loader, IH 886, Cat 1947 D4 dozer, IH 966, Ford 7000, IH 2500, IH 706 and other toys
just reverse the battery cables.... if some one has added an amp meter then the wires on it need to be reversed also i be-live or it will read backwards ... nothing else on the machine cares it its pos or neg ground
2010 with 622 dozer with mod. 35 ripper and a 2010 with 622 dozer bought in 1969 and a 2010 loader with drott and mod. 36 ripper
- vailvalley59
- 430 crawler
- Posts: 51
- Joined: Fri Apr 11, 2014 7:50 am
- Location: PA
cold start
It was 32 degrees here this morning--2010 fired right up with the help of primer pump and glow plugs--used the pump several times after start up to keep going. Still seem to have misfiring at certain RPMs --may still be injectors. Had a hard time finding the correct o-rings for primer--(NAPA) --used some old ones I had on hand and they seem to work better. Thanks
2010 diesel loader, IH 886, Cat 1947 D4 dozer, IH 966, Ford 7000, IH 2500, IH 706 and other toys
Who is online