440icd electrical
440icd electrical
Reverser back in. Engine and radiator is in. Hopefully back running be weekend.
Does anyone know if I switched from 12 volt positive ground to negative ground if it would effect anything other than gauge.
Many Thanks, Jaybird
Does anyone know if I switched from 12 volt positive ground to negative ground if it would effect anything other than gauge.
Many Thanks, Jaybird
- gregjo1948
- 350 crawler
- Posts: 1000
- Joined: Mon Aug 30, 2010 5:58 am
- Location: Newark Valley,NY,USA
Lights don't care about polarity. You could run em on 12 volt AC for that matter. Starter motors don't seem to care either. Can't think of anything but the ammeter that needs to be changed. Not familiar with that tractor but if it has a generator that would need to be polarized. An alternator would need to be changed out or severely modified internally.
Hal in Lee, ME
JD 420c, Cat D4, Farmall H
JD 420c, Cat D4, Farmall H
- gregjo1948
- 350 crawler
- Posts: 1000
- Joined: Mon Aug 30, 2010 5:58 am
- Location: Newark Valley,NY,USA
Seems like 12 volts would over power 6 volt bulbs and blow them. gregjo1948
JD 350B diesel 6way blade, Case 580B Loader/backhoe, Farmall 504 high crop w/ flail boom mower, International 404 , International 284 diesel w/belly mower, 1972 Ford F600 dump truck, Galion 3-5 roller, Allis Chalmers D17, 1620 Ford
8 volts will severely shorten the life of 6 volt bulbs. Don't ask me how I know.
Bryce
Bryce
No trees were hurt in the creation of this message.
But, many electrons were terribly bothered.
440IC/602, 2-440ICD/831 MM UBU-LP, 445N-LP, 445E-LP, BIG MO 400-M, 4 Star-LP M5-D, M5-LP, M602-LP, M670-LP, G900-LP, G900-D, G1000 Vista-LP Case 580CK
But, many electrons were terribly bothered.
440IC/602, 2-440ICD/831 MM UBU-LP, 445N-LP, 445E-LP, BIG MO 400-M, 4 Star-LP M5-D, M5-LP, M602-LP, M670-LP, G900-LP, G900-D, G1000 Vista-LP Case 580CK
THE question was" I switched from 12 volt positive ground to negative ground if it would effect anything other than gauge" he all ready had 12 volt so lets assume he had changed the bulbs all ready
2010 with 622 dozer with mod. 35 ripper and a 2010 with 622 dozer bought in 1969 and a 2010 loader with drott and mod. 36 ripper
- gregjo1948
- 350 crawler
- Posts: 1000
- Joined: Mon Aug 30, 2010 5:58 am
- Location: Newark Valley,NY,USA
Gotcha!jtrichard wrote:THE question was" I switched from 12 volt positive ground to negative ground if it would effect anything other than gauge" he all ready had 12 volt so lets assume he had changed the bulbs all ready
JD 350B diesel 6way blade, Case 580B Loader/backhoe, Farmall 504 high crop w/ flail boom mower, International 404 , International 284 diesel w/belly mower, 1972 Ford F600 dump truck, Galion 3-5 roller, Allis Chalmers D17, 1620 Ford
- Stan Disbrow
- 350 crawler
- Posts: 2904
- Joined: Fri Jul 15, 2005 3:13 pm
- Location: Raleigh, NC
Hi,
One has to repolarze the generator. And, as noted, swap the leads on the ammeter (or just live with having to read it backwards).
Stan
One has to repolarze the generator. And, as noted, swap the leads on the ammeter (or just live with having to read it backwards).
Stan
There's No Such Thing As A Cheap Crawler!
Useta Have: '58 JD 420c 5-roller w/62 inside blade
Useta Have: '78 JD350C w/6310 outside blade
Useta Have: '68 JD350, '51 Terratrac GT-25
Have: 1950 M, 2005 x495, 2008 5103 (now known as 5045D)
Useta Have: '58 JD 420c 5-roller w/62 inside blade
Useta Have: '78 JD350C w/6310 outside blade
Useta Have: '68 JD350, '51 Terratrac GT-25
Have: 1950 M, 2005 x495, 2008 5103 (now known as 5045D)
- Stan Disbrow
- 350 crawler
- Posts: 2904
- Joined: Fri Jul 15, 2005 3:13 pm
- Location: Raleigh, NC
-
- 2010 crawler
- Posts: 622
- Joined: Tue Mar 30, 2010 8:02 am
- Location: Steubenville, OH
Who is online